11KV Dropout Cutout Single Insulator

RATING & CHARACTERISTICS PRODUCT IMAGE
Normal voltage 11 KV
Max, design voltage 15 KV
Rated continuous current 100 A
Interrupting current (rms) Asym. At 20 % P.F. 10000 A
Impulse withstand voltage to ground 95 KV
Impulse withstand voltage across gaps 110 KV
Dry one minute Power frequency withstands voltage to ground 35 KV
Dry one minute power frequency withstands voltage across gaps 45 KV
Wet one minute power frequency withstands voltage to ground 30 KV
Limit of radio interference 10 KV and 1000 KC 250 Micro volts
Temperature rise at rated current 30 șC

Back  

11KV Dropout Cutout Fuses (Double Insulator)

RATING & CHARACTERISTICS PRODUCT IMAGE
Nominal voltage 11KV
Maximum design voltage 12KV
Rated continuous current 100amp
Interrupting current assym amps (rms) at 20% p.f. 8000 amp
Impulse withstand voltage to ground 95 KV
Impulse withstand voltage across gap 110KV
Dry one minute power frequency withstand voltage to ground 35KV
Dry one minute power frequency withstand voltage across gap 45KV
Wet one minute power frequency withstand voltage to ground 30KV
Limit of radio interference 10KV and 1000KC 250 micro volts
Temperature rise at rated current 30 șC

Back  

33KV Dropout Cutout Fuses Double Insulator

RATING & CHARACTERISTICS PRODUCT IMAGE
Voltage Rating 33 KV
Max. Design Voltage 38 KV
Impulse Withstand Voltage 200 KV
Dry One Minute Withstand Voltage 95 KV
Wet Withstand Voltage 80 KV
Rated Continuous Current 100 Amps
Interrupting Rating (Symm) 5000 r.m.s amps
Temperature Rise at Rated Current 30 șC

Back  

11KV Dropout Cutout "A" Type (KESC)

RATING & CHARACTERISTICS PRODUCT IMAGE
Nominal voltage 11KV
Maximum design voltage 12KV
Rated continuous current 100amp
Interrupting current (symm) amps (rms) at 20% p.f 8000 amp
impulse without voltage across ground 110 KV
dry one minute power frequency without voltage to ground 35
withstand voltage across gap 45KV
wet one minute power frequency withstand voltage to ground 30KV
limit of radio interference 10KV and1000KC 250mi
temperature rise at rated current 30 șC

Back  

 

11KV Dropout Cutout "D" Type (KESC)

RATING & CHARACTERISTICS PRODUCT IMAGE
Nominal voltage 11KV
Maximum design voltage 12KV
Rated continuous current 100amp
Interrupting current assym amps (rms) at 20% p.f. 8000 amp
Impulse withstand voltage to ground 95 KV
Impulse withstand voltage across gap 110 KV
Dry one minute power frequency withstand voltage to ground 35
Dry one minute power frequency withstand voltage across gap 45KV
Wet one minute power frequency withstand voltage to ground 30KV
Limit of radio interference 10KV and 1000KC 250mi
Temperature rise at rated current 30 șC